1、

This criterion uses the fault location result to get the fault point voltage and take the fault point voltage in theory as the setting value to distinguish the permanent fault from temporary fault.

该判据以故障点瞬时故障电压理论值为定值,由故障测距结果求出故障点实际电压,当故障点实际电压小于定值时为永久性故障,反之为瞬时性故障;

互联网摘选

2、

setting method on the optimal reclosing time for a permanent fault based on network dynamic variables

基于网络信息的永久性故障重合闸优化时间整定方法

互联网摘选

3、

adaptive setting in optimal reclosing time for permanent fault

永久性故障最佳重合闸时间的自适应整定方法

互联网摘选

4、
5、

Research and Implementation about Permanent Fault Recovery Mechanism of a TMR Sever

一种TMR容错服务器永久故障恢复机制的研究与实现

互联网摘选

6、

The results show that recovery voltage of temporary fault contains the components of power frequency component and free component, while the recovery voltage of permanent fault only contains power frequency component.

研究表明单相瞬时性故障时的恢复电压由自由分量与工频分量叠加而成,而永久性故障时的恢复电压中只包含工频分量。

互联网摘选

7、

A novel approach of distinguishing between temporary and permanent fault in single pole autoreclosing based on fault location is proposed.

该文提出一种基于故障测距的单相自动重合闸永久故障电压自适应补偿判据。

互联网摘选

8、

Permanent Magnetic DC Motor Fault detection and Diagnosis Based on Current Analysis

基于电流分析的永磁直流电动机故障检测与诊断

互联网摘选

9、

The similarities of the amplitudes and phases between the voltage of opened phase conductor and the sum voltage of two healthy phases are all included in the criterion so that the correlation coefficient of a temporary fault is larger than that of a permanent one.

该判据综合考虑了断开相计算电压与两健全相电压和的幅值与相位的相似性,使瞬时性故障时的相关系数大于永久性故障时的相关系数。

互联网摘选

10、

When a process page faults on a file ( meaning the process references a part of the file that is not currently cached in memory in a permanent storage page), the process generates a page fault.

当对某个文件出现进程缺页(意味着该进程引用了文件的部分内容,而这部分内容当前没有缓存在永久存储分页的内存中)的时候,该进程将产生一个缺页。

互联网摘选

11、

A Method of Determining the Relative Winding Axises Position of Dual-Stator Permanent Magnet Electrical Machine Research on Rotor Bar Breaking and Stator Winding Inter-Turn Short Circuit Double Fault in Squirrel Cage Induction Motors

双定子永磁电机内外定子绕组相轴相对位置确定方法笼型异步电动机转子断条与定子绕组匝间短路双重故障研究

互联网摘选

12、

In order to greatly enhance the zero-sequence current active component during the single-phase ground fault, the short-time switch and the resistance paralleled with the petersen coil were controlled when there is a permanent single-phase ground fault in the system.

该方法当系统发生永久性单相接地故障时通过控制开关短时投切与消弧线圈并联的电阻,从而大大增强单相接地故障时的零序电流有功分量。

互联网摘选

13、

Under the action of equivalent force which intensity is 1. 103 × 1013N, the curst derm of north-east segment of seismic fault had finished the uprise permanent non-restoring deformation during 20. 46 minutes time process, after the major earthquake occurred.

在强度为1.103×10~(13)牛顿的等效力作用下,地震断层东北盘的地壳表层物质在主震发生后,经20.46分钟的时间过程完成了向上抬升的永久性不回复形变。

互联网摘选